The SulfiLoggerTM H2S sensor is an robust device for continuous liquid-phase and inline monitoring of hydrogen sulfide in rough environments. The sensor’s reliable insights enable you to adopt a proactive and data-driven approach to odor and corrosion control in wastewater, biogas, oil & gas, and other industries.
Sensor models:
Full certifications on sulfilogger.com/support
Reliable insights
Measure H2S anywhere
The robust SulfiLogger™ H2S sensor can be installed virtually anywhere in industrial applications, giving you accurate and reliable measurements to solve odor and corrosion control challenges based on data instead of hunches.
uninterrupted data
Know the H2S challenge
The sensor’s uninterrupted, continuous data provides a complete picture of how sulfide levels change over time, revealing both daily fluctuations, seasonal variations, and sudden spikes that could be missed with conventional measurement solutions.


Easy installation & low maintenance
Simplify the H2S monitoring setup
The SulfiLogger™ H2S sensor is designed for simple and direct installation. It can be submerged directly in raw wastewater or inserted inline in a wet gas stream with no need for complex sampling systems or gas preconditioning.
Sulfilogger™ H2S sensor
Specifications
| H2S sensor models | |
|---|---|
SulfiLoggerTM S1/X1-1020 |
|
| Application | Wastewater |
| Measurement media |
|
| Measurement range | Low range 0-0.5 mg/L 0-100 ppm |
| Normal range 0-5 mg/L 0-1000 ppm |
|
| Custom range Custom measurement ranges upon request |
|
| Max pressure | 3 barg (44 psig) |
| Operating temperature range | 0 °C to +40 °C (32 °F to +104 °F) |
| Front design | Passive anti-fouling flush front for sensor submersion |
| Material | Stainless Steel EN 1.4404 (316L) |
SulfiLoggerTM S1/X1-1120 |
|
| Application | Biogas |
| Measurement media |
|
| Measurement range | Low range 0-0.5 mg/L 0-100 ppm |
| Normal range 0-5 mg/L 0-1000 ppm |
|
| Custom range Custom measurement ranges upon request |
|
| Max pressure | 3 barg (44 psig) |
| Operating temperature range | 0 °C to +40 °C (32 °F to +104 °F) |
| Front design | Threaded G 1″ (ISO 228-1, BSPP) |
| Material | Stainless Steel EN 1.4404 (316L) |
SulfiLoggerTM X1-1220 |
|
| Application | Oil & gas |
| Measurement media |
|
| Measurement range | Low range 0-0.5 mg/L 0-100 ppm |
| Normal range 0-5 mg/L 0 1000 ppm |
|
| Custom range Custom measurement ranges upon request |
|
| Max pressure | 3 barg (44 psig) Custom pressure rating upon request |
| Operating temperature range | 0 °C to +60 °C (32 °F to +140 °F) |
| Front design | Threaded G 1″ (ISO 228-1, BSPP) |
| Material | Surface treated stainless steel for improved corrosion resistance EN 1.4404 (316L) |
| H2S sensor models | |||
|---|---|---|---|
SulfiLoggerTM S1/X1-1020 |
SulfiLoggerTM S1/X1-1120 |
SulfiLoggerTM X1-1220 |
|
| Application | Wastewater | Biogas | Oil & gas |
| Measurement media |
|
|
|
| Measurement range | Low range 0-0.5 mg/L 0-100 ppm |
Low range 0-0.5 mg/L 0-100 ppm |
Low range 0-0.5 mg/L 0-100 ppm |
| Normal range 0-5 mg/L 0-1000 ppm |
Normal range 0-5 mg/L 0-1000 ppm |
Normal range 0-5 mg/L 0-1000 ppm |
|
| Custom range Custom measurement ranges upon request |
Custom range Custom measurement ranges upon request |
Custom range Custom measurement ranges upon request |
|
| Max pressure | 3 barg (44 psig) | 3 barg (44 psig) | 3 barg (44 psig)
Custom pressure rating upon request |
| Operating temperature range | 0 °C to +40 °C (32 °F to +104 °F) | 0 °C to +40 °C (32 °F to +104 °F) | 0 °C to +60 °C (32 °F to +140 °F) |
| Front design | Passive anti-fouling flush front for sensor submersion | Threaded G 1″ (ISO 228-1, BSPP) | Threaded G 1″ (ISO 228-1, BSPP) |
| Material | Stainless Steel EN 1.4404 (316L) | Stainless Steel EN 1.4404 (316L) | Surface treated stainless steel for improved corrosion resistance EN 1.4404 (316L) |
| Technical specifications | |
|---|---|
| Accuracy | +/- 5% of reading |
| Detection limit | 1% of full range |
| Response time | <25 seconds |
| Operating humidity range | 0-100% |
| Max water depth | 10 metres |
| Storage temperature range | 0 °C to +40 °C (32 °F to +104 °F) |
| Design temperature range | -20 °C to +60 °C (-4 °F to +140 °F) |
| Power input options |
|
| Data output options |
|
* With the PowerCom Box only.
| Mechanical & other specifications | |
|---|---|
| Length | 240 mm (9.4 in) |
| Diameter | 48.3 mm (1.9 in) |
| Weight | 0.85 kg (1.9 lb) |
| Warranty | 2 years** |
| Chemical interferences specifications | |
** When used in accordance with the Installation Manual.
| Certification | |
|---|---|
S1-series:![]() ![]() ![]() |
|
X1-series:![]() ![]() ![]() ![]() ![]()
|
*** SulfiLogger™ X1 only. Certificates are available on sulfilogger.com/support.
Used in +30 countries
Trusted by the industry
PRICING
Request sensor pricing
The price of a SulfiLogger™ H2S sensor system depend on your specific application, which impacts which sensor configuration and what pieces of mounting hardware is required. Therefore, before we can give you a quote, we need to understand your application.