H2S detector for rough environments

Measure H2S anywhere

Continuously monitor hydrogen sulfide levels in wastewater, air, and process gases with the game-changing SulfiLoggerTM H2S detector – a robust device that delivers superior insights in rough environments.


X1 series detectors

Inline H2S detector for industrial applications

Measure H2S in extreme environments in wastewater, biogas, oil & gas, and other industries including aquaculture, pulp & paper, and industrial manufacturing.

Wastewater

Continuously measure H2S directly in wastewater for superior insights in sewer networks and at wastewater treatment plants.

Biogas

Monitor H2S continuously in wet biogas immediately after the anaerobic digester or desulphurization processes.

Oil & Gas

Measure right after the oil & gas separator to follow the development in H2S and to eliminate the need for manual sampling.

Benefits

Get the right H2S data, with no interruptions and minimal hassle, and take your odor and corrosion control strategy to the next level.

Get the right H2S data…

Measure H2S directly in untreated wastewater or wet gases for superior insights.

  • Measure in 0-100% humidity
  • Measure in wastewater, gases, or air
  • Measure in high temperature/pressure
…with no interruptions…

Get insights on any time scale to spot seasonal effects, daily patterns, and unexpected spikes.

  • Continuous data

  • Long-term data with no dry-out needed
  • Data in SCADA, in the cloud, or via RS-232
… and minimal hassle.

Get started and keep the detector’s high accuracy over time with minimal hassle.

  • SulfiLogger supplies all mounting hardware
  • No preconditioning or sampling needed

  • 10-minute calibration every 3rd month

H2S detector specifications

The SulfiLoggerTM H2S detector uses a novel and patent-pending technology that is robust in challenging environments.

H2S sensor models

SulfiLoggerTM S1/X1-1020

Measurement media Wastewater (mg/L)
Air (ppm)
Measurement range Low range
0-0.5 mg/L
0-100 ppm
Normal range
0-5 mg/L
0-1000 ppm
Custom range
Custom measurement ranges upon request
Max pressure 3 barg (44 psig)
Operating temperature range 0 °C to +40 °C
(32 °F to +104 °F)
Front design Passive anti-fouling flush front for sensor submersion
Material Stainless Steel
EN 1.4404 (316L)
Price
SulfiLoggerTM S1/X1-1120
Measurement media Pressurized wastewater (mg/L)
Biogas (ppm)
Measurement range Low range
0-0.5 mg/L
0-100 ppm
Normal range
0-5 mg/L
0-1000 ppm
Custom range
Custom measurement ranges upon request
Max pressure 3 barg (44 psig)
Operating temperature range 0 °C to +40 °C
(32 °F to +104 °F)
Front design Threaded G 1″
(ISO 228-1, BSPP)
Material Stainless Steel
EN 1.4404 (316L)
Price
SulfiLoggerTM X1-1220
Measurement media Pressurized process water (mg/L)
Natural gas (ppm)
Measurement range Low range
0-0.5 mg/L
0-100 ppm
Normal range
0-5 mg/L
0-1000 ppm
Custom range
Custom measurement ranges upon request
Max pressure 3 barg (44 psig)
Custom pressure rating upon request
Operating temperature range 0 °C to +60 °C
(32 °F to +140 °F)
Front design Threaded G 1″
(ISO 228-1, BSPP)
Material Surface treated stainless steel for improved corrosion resistance
EN 1.4404 (316L)
Price
H2S sensor models
SulfiLoggerTM S1/X1-1020 SulfiLoggerTM S1/X1-1120 SulfiLoggerTM X1-1220
Measurement media Wastewater (mg/L)
Air (ppm)
Pressurized wastewater (mg/L)
Biogas (ppm)
Pressurized process water (mg/L)
Natural gas (ppm)
Measurement range Low range
0-0,5 mg/L
0-100 ppm
Low range
0-0,5 mg/L
0-100 ppm
Low range
0-0,5 mg/L
0-100 ppm
Normal range
0-5 mg/L
0-1000 ppm
Normal range
0-5 mg/L
0-1000 ppm
Normal range
0-5 mg/L
0-1000 ppm
Custom range
Custom measurement ranges upon request
Custom range
Custom measurement ranges upon request
Custom range
Custom measurement ranges upon request
Max pressure 3 barg (44 psig) 3 barg (44 psig) 3 barg (44 psig)
Custom pressure rating upon request
Operating temperature range 0 °C to +40 °C
(32 °F to +104 °F)
0 °C to +40 °C
(32 °F to +104 °F)
0 °C to +60 °C
(32 °F to +140 °F)
Front design Passive anti-fouling flush front for sensor submersion Threaded G 1″
(ISO 228-1, BSPP)
Threaded G 1″
(ISO 228-1, BSPP)
Material Stainless Steel
EN 1.4404 (316L)
Stainless Steel
EN 1.4404 (316L)
Surface treated stainless steel for improved corrosion resistance
EN 1.4404 (316L)
Price
Technical specifications
Accuracy +/- 5% of reading
Detection limit 1% of full range
Response time <25 seconds
Operating humidity range 0-100%
Max water depth 10 metres
Storage temperature range 0 °C to +40 °C

(32 °F to +104 °F)

Design temperature range -20 °C to +60 °C

(-4 °F to +140 °F)

Power input options 4-20 mA loop power

DC power (12-28 VDC)

Batteries*

Data output options 4-20 mA analogue signal

RS-232 digital signal

Cloud data*

* With the PowerCom Box only.

Mechanical & other specifications
Length 240 mm (9.4 in)
Diameter 48.3 mm (1.9 in)
Weight 0.85 kg (1.9 lb)
Warranty 1 year**
Chemical interferences specifications

** When used in accordance with the Installation Manual.

Certification
S1-series:
X1-series:

  • ETL listed (cETLus marked) to Canadian and US General Safety and Hazardous (Class l, Div. 1) Locations***
  • ATEX, UKEX, and IECEx approved for use in Zone 0 Hazardous Areas (Ex II 1G Ex ia IIC T4 Ga)***

*** SulfiLogger™ X1 only. Certificates are available on sulfilogger.com/support.

Book a meeting

Do you want to know more about the SulfiLoggerTM H2S detector?

Book an introductory online meeting by filling out the form.
Our measurement experts will then schedule a meeting with you via Microsoft Teams to discuss your needs.
You are also welcome to request a quote or ask questions using the form.